Lumiform
Features Solutions Resources Templates Enterprise Pricing
Select a language
Englishen
Deutschde
Françaisfr
Españoles
Português (BR)pt-BR
en
Contact salesLog in
Sign up
Back
Englishen
Deutschde
Françaisfr
Españoles
Português (BR)pt-BR
Features Solutions Resources Templates Enterprise Pricing
Free demo
Log in
en
Book a personal demoView video demoContact sales
Explore
Resource hubCentral repository for all Lumiform resourcesCustomer storiesReal-world successes and experiences with Lumiform.
Learn
Template collectionsComprehensive collections of best practice templates.Topic guidesComprehensive safety, quality, and excellence insights.LexiconDefinitions key to quality, safety, and compliance.
Support
Developer's guideTechnical documentation for developers.Help centerAssistance with onboarding and platform mastery.
Featured reads
Explore our collection of 38 free preventive maintenance checklists

Template collection

Explore our collection of 38 free preventive maintenance checklists

Start reading
Your guide to performing and documenting efficient child care observation

Topic guide

Your guide to performing and documenting efficient child care observation

Start reading
Lumiform as customer journey mapping tool in gastronomy

Success story

Lumiform as customer journey mapping tool in gastronomy

Start reading
Book a personal demoView video demoContact sales
By industry
Food and hospitalityManufacturingConstructionRetailTransport and logisticsFacility managementView all industries
By business needs
Health and safety managementQuality managementOperational excellenceRisk management and complianceView all business needs
By use case
Safety management softwareEnergy audit appForklift inspection appBuilding management softwareVehicle inspection appQMS appKaizen method appProperty inspection appRestaurant inspection appElevator management appProject management softwareFire inspection app
View all app uses
Book a personal demoView video demoContact sales
Overview
Template libraryDiscover over 12,000 free, ready-made and expert proofed templates.
Use cases
CleaningMaintenanceRisk assessmentSupply chainIncident management
Business needs
Health and safety managementQuality managementOperational excellenceRisk management and compliance
Industries
Food and hospitalityManufacturingRetailTransport and logisticsConstructionFacility management
Book a personal demoView video demoContact sales
Overview
Product overviewAll features
Capabilities
Digitize
Form builderMobile AppActions
Automate
Workflow automationApprovalsIntegrations
Transparency and accountability
ReportsAnalytics
Orchestrate
Administration
Book a personal demoView video demoContact sales
Templates
Coiled Tubing Rig Up Checklist

Coiled Tubing Rig Up Checklist

This template can be used to document the installation of new spiral hoses.

Use this template
or download pdf
Coiled Tubing Rig Up Checklist

This template can be used to document the installation of new spiral hoses.

Use this template
or download pdf

About the Coiled Tubing Rig Up Checklist

A Coiled Tubing Rig Up Checklist is a document used in the oil and gas industry to ensure that coiled tubing equipment is installed properly. The checklist includes tasks such as verifying the equipment’s functionality and safety features and confirming that all components are installed according to industry standards.

The Importance of Coiled Tubing Rig-Up Checklists in the Oil and Gas Industry

A Coiled Tubing Rig Up Checklist is an essential document used in the oil and gas industry to ensure the proper installation of coiled tubing equipment. It includes various tasks that must be carried out during the installation process, such as verifying the equipment's functionality and safety features, and confirming that all components are installed according to industry standards.

The checklist is used to ensure that the coiled tubing equipment is installed properly, reducing the risk of equipment failure and downtime. Additionally, it helps to ensure that all safety measures are in place, reducing the risk of accidents and injuries to personnel.

By using a Coiled Tubing Rig Up Checklist, companies can ensure that their coiled tubing equipment is installed and maintained to the highest industry standards. This, in turn, helps to increase operational efficiency, reduce downtime, and improve overall safety in the workplace.

Related categories

  • Maintenance templates
  • Workplace safety templates
Preview of the template
Audit
Coiled Tubing Rig Up Checklist
Document Number: TES-HS-1037
Revision Level: 1.0
Release Date: 03/28/2013
Customer Location
Date (mm/dd/yy)
Arrival Time (24 hours)
Departure Time (24 Hours)
Name
Field Supervisor
Note: This form must be submitted to Division HSSE specialist & Corporate QHSSE Manager prior to running in hole.
Inspection Items
HSE
ERP, emergency contacts, driving directions and GPS are posted
Certification papers delivered with equipment
Smoking area butt container out in smoking area
Suitable amount of facilities
8ft of 10ft ground rod buried at least 2.5ft into ground
PVC ground rod covers in place for visibility
Spotters have on Hi Vis vest when spotting equipment
Sufficient quantity of absorbent materials on location
75ft buffer zone from all pressure sources
MSDS for all chemicals on location
Fire extinguishers out and hanging on front of equipment
Trip hazards clearly marked
Appropriate signage installed
Shower trailer set up at minimum 55ft from chemical area and function tested
All containers labeled
Equipment physical appearance (rust, paint, etc.)
Iron certifications within annual requirement and banded
All JSEA's signed
Fuel trailer grounded and bonding cable installed and available for use when fueling
Employees have correct PPE available for use
Extra PPE inventory available on location
Are wheel chicks available for vehicles
All containments in place / sides upright/ bridges installed
Lifting equipment is inspected and register up to date
Fall Protection inspected and register up to date
Controlled work instructions on site
Chemical Transport manifest on site and signed by the driver
CTU
Annual inspection of CT gauges reviewed
Confirm Weight indicator is functioning
PUMP
Double pump outlets capped or plugged (no open loops)
Check valve for kill line or remote operated valve (pump to reel)
PSV annual inspections
PSV for fluid pump and electronic trip or Pre-set PSV
Fluid Line anchored at each end.
BOP
Current BOP Certification
BOP has pressure test within 14 days of arrival
BOP function test
Shear ram performance test within previous 180 days
Confirm BOP Ram Configuration per NOP/WSP
Check for short bolting on BOP components prior to rig up
Flange connection only-BOP to Wellhead
INJECTOR HEAD
Certified rigging on IH (slings, D-rings, Shackles, etc)
Inspection and weight rating documentation for pad eyes
IH chain guards properly secured, secondary tether installed
Keepers on bolts/lock nuts installed
Fall restraint not deployed (SRL Sala Block)
Hydraulic lines restrained (BOP, IH)
IH stabilizer lines and anchors secure and correct come alongs used?
CRANE
Crane Anemometer installed and functional
Daily crane inspection forms in crane cab and available for review (max 30 days all others brought to yard for records)
Confirm anti two block test
Lifting equipment is inspected and register up to date
Checklist Completed By
Name (Please Print)
Date/Time
*Note: N2 Rig Up Checklist must be submitted along with this report if N2 is being used for operation.
Comments
This template was downloaded 130 times

More templates like this

Real Estate Contract to Close Checklist Template
Real Estate Contract to Close Checklist Template
This real rstate contract to close checklist is used for quality control from listing to contract to conclusion.
Templates for business processes
Combined Internal ISM ISO ISPS Audit
Combined Internal ISM ISO ISPS Audit
This checklist is a combined audit for ISM, ISO and ISPS. It is used by inspectors for ships to ensure that all regulations are complied with.
ISO templates
Compliance Inspection
Compliance Inspection
Use this template to check whether all regulations are complied with in the company.
Maintenance templates

This template, developed by Lumiform employees, serves as a starting point for businesses using the Lumiform platform and is intended as a hypothetical example only. It does not replace professional advice. Companies should consult qualified professionals to assess the suitability and legality of using this template in their specific workplace or jurisdiction. Lumiform is not liable for any errors or omissions in this template or for any actions taken based on its content.
Lumiform logo
Platform
HomeSign upProductAll featuresPricingEnterpriseTrust and securityCustomer success offeringsDownload the app
Solutions
IndustriesFood and hospitalityManufacturingConstructionRetailTransport and logisticsFacility management
Business needsHealth and safety managementQuality managementOperational excellenceCompliance and risk management
Uses cases
Learn
Template collectionsTopic guidesLexiconHelp centerJournalInfographicsVideos
Resources
Lumiform templatesby industryby use caseby business needAll categories
Customer storiesDeveloper APIResource hubIntegrations
Company
AboutJobsLegalBook a demoContact sales
© 2025 LumiformTerms and conditionsPrivacyData processingSitemap