Carry out maintenance of refrigeration systems according to general regulations using a digital checklist.
A chiller maintenance checklist is used to assess if commercial chillers are maintaining the setpoint to achieve maximum efficiency.
Download templateThis template can be used by refrigeration plant operators and maintenance staff to inspect different types of industrial chillers such as centrifugal, screw, piston and absorption chillers on a daily basis.
Download templateThis template is used by maintenance managers to schedule weekly or monthly inspections.
Download templateA chiller commissioning checklist is used to thoroughly record observations before and after the start-up of chiller systems.
Download templateA chiller maintenance checklist is used by maintenance technicians to evaluate the operating condition of a commercial refrigeration system during a scheduled inspection. It is also used by operators and maintenance personnel for daily temperature measurements. A chiller maintenance checklist is a useful tool for taking preventive measures to avoid costly breakdowns.
The chiller maintenance includes, according to general regulations, scheduled inspections of commercial or industrial equipment with the aim of extending the service life and maintaining optimum efficiency. Insufficiently maintained refrigeration systems lead to poor performance and increased costs.
1. Components of the chiller maintenance
2. Difficult failures of chiller systems that should be rectified immediately
3. Digital technology for trouble-free, daily temperature measurements
The cooling system to function properly, the pressure, temperature, superheat, and subcooling of the cooling system must be controlled. Thanks to digital applications, e.g. a leak test of refrigeration systems with a form, abnormalities and sources of error can be quickly detected and corrected. Thanks to the digital software solution, you can be sure that you minimize sources of error and save yourself a lot of paper chaos. The main components of maintenance for refrigeration systems are listed below:
Leaks in the cooling system often lead to serious damage to the cooling system and ultimately to the environment. The prescribed and necessary cooling capacity is no longer available, which can also extend to other areas of the chiller system.
For the maintenance of refrigeration systems, the temperature of the device itself must be measured without errors, as well as the ambient air or the core temperature of the refrigerated goods.
Measure, record and document relative humidity in the storage room precisely. The humidity in the storage room has the same effect on the refrigeration system as the temperature of the system itself.
Multimeter, current clamp, current tester and voltage tester are subject to regular inspection. Electronic parameters such as current, voltage or resistance must be carefully checked during maintenance for refrigeration systems.
Even professional technicians and operators of chiller systems make the mistake of neglecting regular inspections. It is significant for the efficiency of a system that all employees carry out maintenance tasks carefully. In this way, minor problems are immediately detected and solved before they get worse. The three most common signs of refrigeration system inefficiency are:
If the temperature difference between the supply and return water is higher than intended, impurities may accumulate in the evaporator and condenser tubes. One measure can, therefore, be to improve the current water treatment system or to subject the cooling tubes to regular chemical cleaning. Since the efficiency of heat transfer is directly related to the efficiency of the cooler, all pipes should be kept free of sludge, scale and algae.
If the condenser pressure rises continuously within a month, the water flow rate may be incorrect. This reduces the efficiency of the cooling system. The control system can be calibrated by regularly removing deposits on the internal parts with a low-pressure fan. Condenser pressure and compressor capacity are also increased by non-condensable materials or trapped air and moisture, which ultimately leads to higher power consumption.
If a chiller system permanently fails to reach full cooling load, the oil may have migrated into the refrigerant, which harms the refrigerant level. If the oil properties change, this means considerable compressor wear. If liquid refrigerant enters the compressor and evaporates, this will result in reduced refrigeration capacity, an overloaded motor and damage to the compressor impeller.
The daily chiller maintenance systems according to regulations usually includes the manual keeping of maintenance logs - this is stressful and time-consuming. With Lumiform, the powerful inspection platform, technicians never miss a maintenance check again. Equipped with new temperature sensors, responsible personnel can now perform the following more efficiently:
The flexible Analysis Tab. Here you can access all data and view your performance reports broken down by time, location and department. This helps you quickly identify causes and problems so you can fix them as quickly as possible.
Monitor your team’s inspection performance and identify opportunities to improve the process and efficiency of your operations.
Connect Lumiform’s Software to enterprise software systems.
Keep an eye on what’s happening and identify insights from the information gained to increase your efficiency.